Specifications

TUBING SET

Separation chamber volume: 40 mL
Number of collection bags: 6
Plastic: non-pyrogenic, biocompatible, sterilized with ethylene oxide

USER CONFIGURABLE PROFILES

Nine, including a sample monocyte enrichment protocol

MANUAL MODE

Pumps, centrifuge speed and ramp rates are fully controlled by the operator

EQUIPMENT

Centrifuge speed: 300 rpm to 2,600 rpm
Pump flow rates: 0 mL/min to 150 mL/min
Elutriation media volume: 500 mL to 12,000 mL
Fraction collection capability: 12

EQUIPMENT

Weight: 177 kg (389 lb)
Height: 180.3 cm (71 in)
Width: 70 cm (27.6 in)
Depth: 68 cm (26.7 in)

LINE VOLTAGE

100 ± 10% V AC, 50/60 Hz
115 ± 10% V AC, 50/60 Hz
230 ± 10% V AC, 50/60 Hz
240 ± 10% V AC, 50/60 Hz

INPUT LINE CURRENT

8 A maximum RMS at 100/115 V AC
4 A maximum RMS at 230/240 V AC

1Read EJ, Carter CS, Khuu HM, Taylor L, Taga TM. Evaluation of a closed automated system to isolate PBMC for DC immunotherapy. Cytotherapy. 2003;5(5,Suppl):456.

2 Powell DJ, Brennan AL, Zheng Z, Huynh H, Cotte J, Levine BL. Efficient clinical-scale enrichment of lymphocytes for use in adoptive immunotherapy using a modified counterflow centrifugal elutriation program. Cytotherapy. 2009.11(7):923-935.

Typical results based on cell counts from a leukapheresis product collected the previous day from normal donors on a COBE® Spectra Apheresis System. 80 mL to 230 mL products contained 5 to 14 × 109 WBC count, 80 percent to 100 percent mononuclear cell and 1.8 mL to 4.7 mL red blood cell volume.

*Customers are responsible for validating the use of the Elutra system to separate cells for their intended therapy.

​​​​​​​​​​​​​

{{'SEARCH_MODAL_TITLE' | translate }}
{{'SEARCH_MODAL_OR' | translate }}

{{'SEARCH_MODAL_BROWSE' | translate }} {{'SEARCH_MODAL_ENLABEL' | translate }}
{{'SEARCH_MODAL_CHOOSE_LANGUAGE' | translate }} {{'SEARCH_MODAL_CHANGE_LANGUAGE' | translate }}
{{$index+1}}. {{s.label}}